Vapour retarder WÜTOP® DB 2

Vapour retarder WÜTOP DB 2
VAPRETARDR-DB02-L50M-W1,5M-75SM
WUETOP

Art.-no.: 0681000004

Prices for customers after login

Vapour retarder WÜTOP<SUP>® </SUP>DB 2

Art.-no.: 0681000004

Prices for customers after login

Quantity

PU

x 75

Exclusively for trade customers

Register now and access more than 15,000 products

Product information

Wuerth Catalogue(X)

Datasheets(X)

Certificates/Documents(X)

Vapour-permeable, moisture-regulating, airtight and particularly easy to install vapour retarder for interior renovations and attic conversions. To be used in conjunction with vapour-permeable underlay membranes and roof protection films
  • Durable and tear-resistant thanks to embedded mesh fabric

  • Prevents heat loss caused by unnecessary airflow

  • Prevents moisture penetration of internal heat insulation and, therefore, the impairment of the insulating effect

  • DB2 2SK with adhesive strips on both sides for permanent airtight/windproof bonding

  • Wütop DB 2 in combination with vapour-permeable roof protection film from the Wütop series provides year-round breathability for insulation and frame structure and creates a healthy indoor climate
null

DIN EN 13984

Instructions

Installation instructions for between-rafter insulation


  • Fix WÜTOP DB 2 to the warm side of the heat insulation using a stapler (hammer tacker or hand-held stapler) and secure with battens

  • The smooth side always faces toward the installer

  • Vertical overlaps must always lie on a rafter

  • Ensure sufficient overlap: Horizontal overlap: at least 10 cm (overlap strip), vertical overlap: approx. 20 cm

  • All overlaps and tacked points must be given an airtight seal using suitable adhesive tape (Eurasol)

  • For airtight attachment to masonry, the membrane is bonded using Wütop film adhesive and secured with a clamping batten, if necessary

  • Take care not to damage the membrane during installation

  • Before the interior cladding (gypsum plasterboard, wood panelling etc.) is attached, check again that the vapour retarder has been correctly installed and correct if necessary


Installation instructions for over-rafter insulation


  • Wütop DB 2 is ideal for use as a vapour retarder for over-rafter insulation

  • Installation: Same procedure as for between-rafter insulation

  • Please note: May be exposed to weather for max. 6 weeks


Installation instructions for renovation of old buildings


  • Sharp objects (e.g. nails) that protrude from the interior cladding into the rafter area must be removed to avoid damaging the vapour retarder

  • Wütop DB 2 is laid over the rafters from the outside with the fleece facing the room interior. Install with the smooth side facing outwards

  • All overlaps and penetrations must be given an airtight seal using suitable adhesive tape (Eurasol)

  • Recommendation: Secure Wütop DB 2 to the rafters using clamping battens

  • Bond joints at the eaves (eave beams/masonry) using Wütop film adhesive. Additional mechanical fixing with clamping battens is recommended

  • The vapour retarder Wütop DB 2 may not be used for the renovation of rooms where the humidity is continually over 60%

  • Pursuant to DIN 4108 Part 3, structures not built using standard construction methods must be verified via calculation (condensate calculation). Therefore, the use of Wütop DB 2 for renovation work must be agreed upon beforehand by Würth Application Support (Phone: +49 (0)7940 15-2552)

Coating weight per m²

116 g

Length of roll

50 m

Roll width

1.5 m

Air layer thickness equivalent to water-vapour diffusion

2.52 m

Weight of roll

9 kg

Resistance to penetration of water

W1

Resistance to tear propagation (transverse)

200 N

Resistance to tear propagation (longitudinal)

220 N

Transverse tensile force per 50 mm

321 N

Longitudinal tensile force per 50 mm

347 N

Min./max. temperature resistance

-40 to 80 °C

Building material class

E

Number of rolls per pallet

30 PCS

In order to guarantee the best service possible, we make use of cookies. This includes use of Google AdWords Remarketing, which displays relevant advertisements to you based on your previous browsing of pages on the Wurth.ie site and e-shop by placing a cookie on your computer. This cookie does not identify you or give us access to your computer. By proceeding to use our services you consent to our use of cookies and the processing of personal data that we collect from you in accordance with our privacy policy. If you do not consent, you must disable cookies or refrain from using the Wurth.ie site and e-shop. Close